BGG Cable Manufacturers
SA (Pty) Ltd.
WalroFlex
 
WalroFlex
 
Make Enquiry





           

Welding Cable (100 V Max)
CONDUCTOR CONSTRUCTION INSULATED CONDUCTOR

Conductor:

BUNCH: SANS 1411-1 Class 5
CORE: SANS 60227-5

Insulation:

PVC/ Nitrile blend. SANS 1576

Packaging:

Bulk on 710 plastic spools or coiled as per requirement
Material type: PVC/ Nitrile blend
Continuous temperature: 70°C
Oil resistant: Yes
Fire Retardancy: Yes (SABS 502)
Insulation thickness: As per SANS 1576
Nominal Cross- Section mm² Number of individual wires Diameter of individual wires mm Bunch Diameter maximum mm Resistance max @ 20 C maximum mÙ/m Insulation wall thickness minimum mm External diameter minimum External diameter maximum Weight approximately kg/1000m
16.0 504 0.200 6.2 1.210 2.0 8.8 11.5 214
25.0 779 0.200 7.2 0.780 2.0 10.0 13.0 308
35.0 1102 0.200 8.8 0.554 2.0 11.0 14.5 410
50.0 1577 0.200 10.6 0.386 2.2 13.0 17.0 577
70.0 2242 0.200 12.5 0.272 2.4 15.0 19.5 800
95.0 2964 0.200 14.3 0.206 2.6 17.0 22.0 1043