BGG Cable Manufacturers
SA (Pty) Ltd.
WalroFlex
 
WalroFlex
 
Make Enquiry





           

FLY W (-40°C / +105°C)

Heat resistant PVC automotive and battery cable

CONDUCTOR CONSTRUCTION INSULATED CONDUCTOR

Conductor:

Annealed Electrolytic Copper Cu-ETP according to DIN EN13602
DIN 72551, part 6, Type B and ISO 67222

Insulation:

PVC (Polyvinyl Chloride - Lead Free)
Plasticide PVC with properties according to DIN 72551
and ISO 6722 Class B

Packaging:

Refer General Information

Ordering example:

FLYW - 1600 - BURD
Type Size Color
Cross Section DIN 72551B 1.5mm² Blue Red
Material type: PVC
Continuous temperature: 105°C (3000h)
Intermittent temperature: 120°C (48h)
Cold resistance: -40°C
Oil resistant: Yes
Fuel resistant: Yes
Abrasion resistance: As per ISO 6722/LV112
Flame resistance: As per ISO 6722/LV112
Insulation wall thickness: Thin wall
Nominal Cross- Section mm² Number of individual wires Diameter of individual wires mm Bunch Diameter maximum mm Resistance max @ 20 C maximum mÙ/m Insulation wall thickness minimum mm External diameter minimum External diameter maximum Weight approximately kg/1000m (Cu/PVC)
0.50 16 0.21 1.0 37.1 0.48 2.0 2.3 8
0.75 24 0.21 1.3 24.7 0.48 2.2 2.5 11
1.00 32 0.21 1.5 18.5 0.48 2.4 2.7 15
1.50 30 0.26 1.8 12.7 0.48 2.7 3.0 20
2.50 50 0.26 2.2 7.6 0.56 3.3 3.6 32
4.00 56 0.31 2.8 4.71 0.64 4.0 4.4 48
6.00 84 0.31 3.4 3.14 0.64 4.6 5.0 68
FLY W (-40°C / +105°C)
Nominal Cross- Section mm² Number of individual wires Diameter of individual wires mm Bunch Diameter maximum mm Resistance max @ 20 C maximum mÙ/m Insulation wall thickness minimum mm External diameter minimum External diameter maximum Weight approximately kg/1000m (Cu/PVC)
10.00 80 0.40 4.50 1.820 0.80 6.00 6.40 117
16.00 126 0.40 6.00 1.160 0.80 7.80 8.30 193
25.00 196 0.40 7.50 0.743 0.98 9.60 10.20 274
35.00 276 0.40 8.30 0.527 1.07 11.10 11.60 397
50.00 396 0.40 10.00 0.368 1.40 13.00 13.50 547
70.00 556 0.40 12.50 0.259 1.20 14.80 15.50 769
95.00 741 0.40 14.80 0.196 1.28 17.00 18.00 990