BGG Cable Manufacturers
SA (Pty) Ltd.
WalroFlex
 
WalroFlex
 
Make Enquiry





           

FLRY- A (-40°C / +105°C)
CONDUCTOR CONSTRUCTION INSULATED CONDUCTOR

Conductor:

Annealed Electrolytic Copper Cu-ETP according to DIN EN13602
DIN 72551, part 6, Type A and ISO 6722 (Concentric Construction)

Insulation:

PVC (Polyvinyl Chloride - Lead Free)
Plasticide PVC with properties according to DIN 72551
and ISO 6722 Class B

Packaging:

Refer General Information

Ordering example:

FLRYA - 0150 - BUWH
Type Size Color
Cable DIN 72551 (A) 1.5mm² Blue White
Material type: PVC
Continuous temperature: 105°C (3000h)
Intermittent temperature: 120°C (48h)
Cold resistance: -40°C
Oil resistant: Yes
Fuel resistant: Yes
Abrasion resistance: As per ISO 6722/LV112
Flame resistance: As per ISO 6722/LV112
Insulation wall thickness: Thin wall
Nominal Cross- Section mm² Number of individual wires Diameter of individual wires mm Bunch Diameter maximum mm Resistance max @ 20 C maximum mÙ/m Insulation wall thickness minimum mm External diameter minimum External diameter maximum Weight approximately kg/1000m
0.22 7 0.20 0.60 84.80 0.20 1.10 1.20 3.10
0.35 19 0.26 0.80 52.00 0.20 1.20 1.30 4.60
0.50 19 0.19 0.96 37.10 0.22 1.40 1.60 6.60
0.75 19 0.23 1.20 24.70 0.24 1.70 1.90 9.00
1.00 19 0.26 1.35 18.50 0.24 1.90 2.10 11.00
1.50 19 0.31 1.70 12.70 0.24 2.20 2.40 16.00
2.50 19 0.41 2.20 7.60 0.28 2.70 3.00 26.00